More information about this CVE will likely be available in a few days

Description


An issue was discovered in Atos Eviden SMC xScale before 1.6.6. During initialization of nodes, some configuration parameters are retrieved from management nodes. These parameters embed credentials whose integrity and confidentiality may be important to the security of the HPC configuration. Because these parameters are needed for initialization, there is no available mechanism to ensure access control on the management node, and a mitigation measure is normally put in place to prevent access to unprivileged users. It was discovered that this mitigation measure does not survive a reboot of diskful nodes. (Diskless nodes are not at risk.) The mistake lies in the cloudinit configuration: the iptables configuration should have been in the bootcmd instead of the runcmd section.

Related CPE's


Could not find any relations

Weaknesses


Could not find any weaknesses

CVSS impact metrics


Could not find any metrics

Information


Source identifier

[email protected]

Vulnerability status

Received

Published

2024-10-11T17:15:03.573

5 months ago

Last modified

2024-10-11T17:15:03.573

5 months ago